Re: Configuring Proxy-arp on a MSX-6036G
I have not configured subnet manager to support pkey 0x236. Then again I can not find a reference to subnet manager in the documentation I am using. MLNX-R307 [standalone: master] # show interfaces...
View ArticleRe: Is it possible to send frames containing L2 CoS and/or L3 DSCP without...
Than the best thing for you to have two types of flows, each one with different L2 priority. and configure the switch with SP to prefer one of the priority on the other.map each priority to different...
View ArticleRe: Configuring Proxy-arp on a MSX-6036G
Hi Carlo, " Bridged interfaces: vlan 1(D), pkey 0x7fff" means that there is no active ports that are members of vlan1.This is because vlan 1 is not on port-channel 2: interface port-channel 2...
View ArticleRe: Configuring Proxy-arp on a MSX-6036G
correction: interface port-channel 2 switchport trunk allowed-vlan add 1
View ArticleRe: Configuring Proxy-arp on a MSX-6036G
OK, interesting. I added vlan 1 to port-channel 2. Port-channel 2 is the Ethernet link to a pair of Arista switches which are supplying vlan 236 as a trunk to the Mellanox switch (BTW it is a 6036G)....
View ArticleRe: Configuring Proxy-arp on a MSX-6036G
Carlo, I dont want to confuse you more.But the concept of the proxy arp is that you map a pkey ( ib partition ) to a vlan. Anyhow i would recommend reading the gateway section in the mlnx-os UM.
View ArticleRe: Is it possible to send frames containing L2 CoS and/or L3 DSCP without...
I’ve done this, assigning 5 to TC2 and 4 to TC1, with 0-3 on TC0. Since priority 4 still permits significant interruption of priority 5 traffic, I want to try lowering it to priority 3, while moving 3...
View ArticleRe: Is it possible to send frames containing L2 CoS and/or L3 DSCP without...
Thanks for your patience. I now seem to have an optimal configuration using the default TC assignments (based on a check of the running-config) of 5 in TC2 for small frames and 2 in TC1 for jumbo...
View ArticleRe: pktgen-dpdk not working on ConnectX-3
Hi Salem, Did you succeed to run testpmd simple test?I did run pktgen with ConnectX3 cards, check the following steps:1. Download latest pktgen version:...
View ArticleWould it be possible to upgrade the PPC cpu boards from my SX1036 switches to...
Well, the title says about all there is to my question; After lots and lots of saving I was finally able to buy a few SX1036 switches, only to find out that mellanox actually sells these switches with...
View ArticleRe: pktgen-dpdk not working on ConnectX-3
Hi Olga, Thanks for your response. I found out that the problem was with compiling DPDK. When I compiled DPDK, I had set CONFIG_RTE_LIBRTE_MLX4_PMD=y on the make command line but apparently that...
View ArticleRe: MLNX-OFED-ESX-2.3.3.1 - Where is a Storage protocol support?
Hello Jae, Please look the release notes to see what is supported. http://www.mellanox.com/related-docs/prod_software/MLNX-OFED-ESXi-5.5_Release_Notes_v2.3.3.txt In order to install VIB, using the...
View ArticleRe: Would it be possible to upgrade the PPC cpu boards from my SX1036...
Hi Bent, once you open the switch cover - the warranty will be voided.you can't replace the CPU of the switch. What is the switch Model you currently have?what SDN features are missing?
View ArticleRe: MLNX-OFED-ESX-2.3.3.1 - Where is a Storage protocol support?
There is a core driver dependencies.Therefore I can't install SRP or iSER vib on 2.3.3.1 driver...:(
View ArticleRe: Mellanox SX Switch Stacking / Mlag Question
is any another SX**** got stacking? maybe like cisco or dlink stacking. but not mlag?
View ArticleConfiguring mgid in partitions ( windows + opensm )
Hello, community. Recently I've tried to install OpenSM on Windows host. It looks to work fine, subnet comes up, ports go to active state and I can send/receive data.I want to define some mgid in my...
View Articlehow to use sample control for port counters
Hello allI want to monitoring ports in IB fabric.I happened to noticein the out of perfquery some counter like a ticksand portsampling. Its will be great for accurate monitoring. But I cant found some...
View ArticleCircuit Breaker in '8-Port QDR IB Switch'
Hello, Could you tell me the capacity & number of the circuit Breaker in '8-Port QDR IB Switch' which is used in EMC Isilon X410 node, please? Best regards,Hiroki
View ArticleRe: Extremely slow ethernet speed with ConnectX VPI card in EN mode.
Hi, I could never get native 10gigE mode to work correctly on the ConnectX-1 cards.I guess mlx4_en driver is broken or 1st gen ConnectX support was removed as these were EOL-ed long time ago. The two...
View Article