Hey Hal,
Firmware is at 2.9.1050:
CA 'mlx4_0' CA type: MT26428 Number of ports: 2 Firmware version: 2.9.1050 Hardware version: b0 Node GUID: 0x0008f104039a72c8 System image GUID: 0x0008f104039a72cb Port 1: State: Down Physical state: Polling Rate: 10 Base lid: 0 LMC: 0 SM lid: 0 Capability mask: 0x02510868 Port GUID: 0x0008f104039a72c9 Link layer: InfiniBand Port 2: State: Down Physical state: Polling Rate: 10 Base lid: 0 LMC: 0 SM lid: 0 Capability mask: 0x0251086a Port GUID: 0x0008f104039a72ca Link layer: InfiniBand
Ok... SO troubleshooting some of the cable si noticed that infiniband ports 1 and 2 stay in "phy-state : port-config-training" regardless of whether a cable is connected or not and the other Infiniband ports stay in 'phy-state : polling' whether a cable is connected or not... Think this is an issue with the switch... So at this point I think I have found the issue. If its all right Id like to correspond back with you once I get a different switch.
Thanks!
Nathan Hawkins